
.. _section_szybki_releasenotes_2601:

Szybki TK 2.6.0.1
================================================================================

* New constant :ref:`SAGE_OPENFF210 <OESz_OEForceFieldType_SAGE_OPENFF210>` has been
  introduced that refers to the Sage 2.1.0 force field. The constant 
  :ref:`SAGE_OPENFF <OESz_OEForceFieldType_SAGE_OPENFF>` now refers to
  this latest version of Sage force field.


Szybki TK 2.6.0.0
================================================================================

New features
--------------------------------------------------------------------------------
* Three classes have been added to facilitate using ff14SB/OpenFF 
  potential for bound ligands and to bypass using OESzybki:

  * :ref:`OEBoundEntropyOptions <OESz_OEBoundEntropyOptions>`
  * :ref:`OELigandEntropyOptions <OESz_OELigandEntropyOptions>`
  * :ref:`OEEntropyResults <OESz_OEEntropyResults>`

* A new function, :ref:`OEBoundLigandEntropy <OESz_OEBoundLigandEntropy>`, has been added
  to calculate the entropy of a bound ligand.

* A new function, :ref:`OELigandEntropy <OESz_OELigandEntropy>`, has been added to calculate the 
  entropy of a free ligand.

* A new pair of options has been added to the :ref:`OETorsionScanOptions <OESz_OETorsionScanOptions>`
  to address hysteresis in torsion scanning. These provide the ability to increase the number of starts
  (:ref:`SetNumStarts <OESz_OETorsionScanOptions_SetNumStarts>`) and address the
  overlaps between scans (:ref:`SetOverlapDiv <OESz_OETorsionScanOptions_SetOverlapDiv>`) to avoid
  doing full 360-degree scans for many starts unless desired.

Major bug fixes
--------------------------------------------------------------------------------
* An issue with the torsion scan (:ref:`OETorsionScan <OESz_OETorsionScan>`) in
  solution with PB solvation has been fixed. It no longer incorrectly uses the
  MMFF94S potential even when
  scanning is done with the OpenFF force field.

* An issue with hysteresis that in certain cases caused asymmetric torsion scans 
  has been addressed by resetting to the starting angle before starting reverse scans.

Minor bug fixes
--------------------------------------------------------------------------------
* Better diagnostics have been added to :ref:`OEFixedProteinLigandOptimizer <OESz_OEFixedProteinLigandOptimizer>`
  when the optimization of a ligand in a fixed protein receptor fails due to an initial clash.
  An appropriate error code is now returned for such cases.
  
* :ref:`OEFlexProteinLigandOptimizer <OESz_OEFlexProteinLigandOptimizer>`
  now provides an appropriate error code when asked to optimize a design unit
  that does not contain a ligand.
