.. _section_omega_releasenotes_241:

Omega TK 2.4.1
================================================================================

New features
--------------------------------------------------------------------------------

*  OMEGA and :ref:`MakeFraglib <chapter_makefraglib>` may now be run with MPI using the `oempirun` script.  (May not available on all platforms)

*  The default for OMEGA has been changed to require all stereocenters to be specified.  Molecules with any unspecified 
   stereo will fail.  The previous
   behavior was for OMEGA to choose a random stereoisomer.  This default can be changed back to the previous behavior 
   by setting `-strictstereo` to ``false``.

*  The default for OMEGA has been changed to no longer use 'close enough' atom typing.  If a proper MMFF atom type 
   cannot be found for 
   an atom then the molecule will fail.  Previous versions would use a different atom type of the same element if it 
   was available.  
   The previous behavior for atom type substitution can be enabled by setting `-strictatomtyping` to ``false``.

*  OMEGA now has the option to require on-the-fly generation of fragments to be the same as the :ref:`MakeFraglib <chapter_makefraglib>` utility
   by setting `-strictfrags` to ``true``. 
   This fragment generation is more rigorous but also more time consuming.

*  The convenience flag `-strict` has been added to turn on or off all of the strict options.  These include 
   `-strictstereo`, `-strictatomtyping` and `-strictfrags`.

*  On-screen progress has been enabled for OMEGA and :ref:`MakeFraglib <chapter_makefraglib>` using the `-progress` flag.
   The options are `none`, `dots`, `log`, and `percent`.

*  The `-maxconfgen` and `-maxpoolsize` flags have been removed.  These options are set internally and adjusted automatically 
   subject to the user
   defined variable of `-maxconfs`.  Additionally, hard limits have been removed from
   these variables and they are now only limited by available memory. 

*  The flag `-fixsmarts` has been created to allow a smarts pattern to be used to fix
   a portion of the molecule.  This requires 3D coordinates to be available from either 
   a 3D input file with `-fromCT` set to ``false`` or from a molecule set using `-fixfile`.


Bug fixes
--------------------------------------------------------------------------------

*  Crashes have been fixed that could occur when the `-fixfile` could not find a valid match or did not have 
   enough atoms to match against in a ring system.

*  Program no longer crashes if there is not enough memory for duplicate removal.  If there is not enough memory 
   available for allocation then the application will exit immediately.
